The role of low-temperature plasma hydrogen peroxide transfer window

Word:[Big][Middle][Small] 2022/11/28     Viewed:    

Although the sterilization function of the low-temperature plasma hydrogen peroxide transfer window is unquestionable, in order to prevent frequent abnormalities and hazards to normal start-up due to errors in actual operation, it is necessary to master the appropriate practical operation of the low-temperature plasma hydrogen peroxide disinfection machine.

<a href='http://www.hfteling.com' style='color:blue;'>过氧化氢消毒机</a>

Before starting, check the appearance of the low-temperature plasma hydrogen peroxide transfer window and whether there are any abnormalities in the power plug. If there are any abnormalities, the cause must be identified before starting.
2. Before starting, check if the negative pressure pump is at the regular liquid level line, if there is any problem with the oil color, and if there is an oil pump on the air filter screen at the exhaust port; If the above-mentioned situation occurs, regardless of whether the oil pump is above or below the normal liquid level line, regardless of whether the oil color is clear or turbid, the oil pump needs to be replaced and the oil mist separator needs to be cleared or replaced.
3. If water or other evaporated chemicals enter the pump cavity, the valve can be opened to carry out purification treatment to solve the problem; Check if there is water or dirt in the air inlet water vapor separator, which can be cleaned or replaced as necessary.
4. When replacing the oil pump, first operate the mechanical pump for about three minutes, then add some oil, and then introduce 100 milliliters of up and down oil into the inlet to clean the oil pump. Wait until all the waste oil is drained before filling the oil pump; Generally, it is sufficient to fill it between half and two-thirds of the oil mirror.
If the low-temperature plasma hydrogen peroxide sterilizer has not been used for more than three days, it is necessary to conduct a system inspection and treatment; Moreover, removing the protective plate on the side of the rotating shaft, it is difficult to rotate the blades of the rotating shaft with proper energy. Therefore, mechanical pump maintenance needs to be carried out.
6. Before disinfection and sterilization, check whether the door sealing ring of the low-temperature plasma hydrogen peroxide sterilizer is clean or deformed; Check if the filter screen at the suction port of the sterilization room is blocked; Check whether there are oil stains and residues in the indoor cavity; Check if the low-temperature plasma transmitter is clean and dry. Check if the hydrogen peroxide is insufficient for one sterilization application.
The hydrogen peroxide transfer window is an air purification system used in the purification room. Suitable for short-term disinfection and sterilization of equipment, objects, and air in small and medium-sized bank credit facilities of different levels of clean rooms and non clean areas, and reasonably reducing the frequency of opening the clean room.
The hydrogen peroxide transfer window is integrated with a gasification hydrogen peroxide generator. The gasification hydrogen peroxide generator provides hydrogen peroxide vapor to the internal structure of the hydrogen peroxide transfer window, and carries out microbial cleaning on the surface of the raw materials to avoid contamination of the raw materials in key areas of A and B. Suitable for cleaning dry and noisy items that need to be transported during the aseptic testing production process, including packaging products, equipment, raw materials, components, environmental monitoring instruments, etc. Enter Class A and Class B heavily polluted areas.